Skip Ribbon Commands
Skip to main content
Use SHIFT+ENTER to open the menu (new window).
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
1
1,403
  
0
0
MetalNAHydro Engineering HE/SI Oil Water SeparatorYes8x12Yes
2
4,504
  
0
Complete
0
Metal8X12Yes
3
3,101
  
0
Complete
0
Concrete40x50, Drive on/Back offHydro Engineering HE/SI Oil Water SeparatorExisting Building
4
1,101
  
1
CompleteNoYesYesBeing Renovated 2001.  Need wash pad and oil water separatorHE01/23/01 Johnson City Water and Sewer (tap $1325); Jim Milhorn 423/461-1646: Building Permits: Marlin Gray(Plumbing Insp.) 423/434-6051: Water Quality; Tom Hensley 423/975-2606
1
Concrete22x36, Drive on/Back offHydro Engineering HE/SI Oil Water Separator (2)8x12 (2)
5
1,102
  
1
NoYesYesNeed wash pad and oil water separatorHE01/25/01 Bristol, TN Water and Sewer; Gary Spry 423/ 989-5649
0
Inside GarageInside GarageHydro Engineering HE/SI Oil Water SeparatorExisting Building
6
1,104
  
1
YesYesNoAppears to have everything needed; may need to inspect current wash pad and add cover to the areaWH01/23/01 Elizabethton Water and Sewer (tap-$1200); Ms. Thompson 423/542-1519: Building Permits ($15.00); Joseph Barnett 423/547-6208: Water Quality; Teresa Nideffer 423/547-6450: Wastewater Treatment Hugh Thomason 547-6345 or Eric Davis 547-6351
1
Information not availableConcreteNAHydro Engineering HE/SI Oil Water SeparatorNoNone
7
1,103
  
0
CompleteNoYesNoParticular specifications include a sand/grit separator to protect proposed pump to sewer.  Need wash pad and oil water separatorAEErwin Utilities; Charles McNabb 423/ 743-1820.  Wastewater: Scott Street:  423/743-1835.
0
Concrete22x32, Drive on/Back offHydro Engineering HE/SI Oil Water Separator8x12Yes
8
1,106
  
0
NoNoNoNo access to sewerXNA
0
NANANoNone
9
1,105
  
0
NoYesYesBeing Renovated 2001.  Need wash pad and oil water separatorHETown of Mountain City; John Parks 423/ 854-5422 and Harvey Burniston 423/ 747-2940
1
Information not availableInside GarageInside GarageHydro Engineering HE/SI Oil Water Separator8x12
10
1,201
  
0
CompleteYes; asphalt pad although it is not covered at this timeYesYesBeing Renovated 2001.WH01/24/01 Morristown Utility Engineer Mike Howard 423-317-6314: 01/25/01 City Engineer Brian Fowler 423-581-0100
1
Concrete22x36, Drive on/Drive offHydro Engineering HE/SI Oil Water Separator8x16
11
1,202
  
1
NoNoNoNo access to sewerNA- tank containment neededETNA
0
NANANoNone
12
1,203
  
1
NoNoNoNo access to sewerNA- tank containment neededETNA
0
NANANoNone
13
1,204
  
0
NoNoNoNo access to sewerNA- tank containment neededSIINSTALLED
1
36944MetalHydro Engineering HE/SI Oil Water SeparatorYes
14
1,301
  
0
CompleteNoYesYesBeing renovated 2001.  Need wash pad; likely need oil/water separator.  Being renovated 2001.HENewport Utilities Board; Carol Proffitt 423/ 625-2848
1
Information not availableConcrete22x36, Drive on/Drive offHydro Engineering HE/SI Oil Water Separator8x12
15
1,302
  
0
NoNoNoNo access to sewerNA- tank containment neededSIINSTALLED
1
36944MetalNAHydro Engineering HE/SI Oil Water SeparatorYes8x12Yes
16
1,303
  
0
NoYesapproximately 800 ft from proposed washpadNoNot specifiedAEDandridge Water & Waste Water Department; Herb Norton 865/ 397-2925
0
NANANoNone
17
1,402
  
0
Not specifiedNoNoNo access to sewerNA- tank containment neededAENA
0
NANANoNone
18
1,403
  
0
NoNoNoNo access to sewerNA- tank containment neededSIINSTALLED
1
36944NANANoNone
19
1,401
  
0
Yes; Wash room located adjacent to garageYes500 ft from buildingNoStep system installation; would require two tanks prior to installation.WALaFollette Utilities Board; Eddie Troxel 423/ 566-9520
1
ConcreteInside GarageHydro Engineering HE/SI Oil Water Separator8x12
20
1,405
  
0
NoYes800 ft from buildingNoNone.  Sewer company is laying the lines now.  Oil/water separator not required, but "it would be nice".  Sand/grit catchment is required.AE02/02/01 Scott County Public Works; Skeet Terry 423/ 569-8039.  Very helpful, fully informed of project.  Step system not required.  Sewer co. is installing a gravity system.  No permits due to location outside city limits.
0
NANANoNone
21
1,404
  
1
NoYesNoStep system installation; Would require 2 tanks to be installed prior to sewer hookuppretreatment tanks, tap fees, piping and pumping stationAEClinton Utilitiy Board; Dan Hawkins 865/ 457-9232
0
NANANoNone
22
1,601
  
0
CompleteYesYesYesBeing renovated 2001.  oil water separator is working fine; no further action requiredWH
1
Concrete22x36, Drive on/Back offHydro Engineering HE/SI Oil Water Separator8x12
23
1,603
  
0
NoYesNoAgainst sanitary sewer guidelinesNA- tank containment neededSI
1
36944MetalNAHydro Engineering HE/SI Oil Water SeparatorYes8x12Yes
24
1,604
  
1
NoNoNoNo access to sewerNA- tank containment neededETNA
0
NANANoNone
25
1,602
  
0
NoNoNoNo access to sewerNA- tank containment neededSIINSTALLED
1
36944MetalNAHydro Engineering HE/SI Oil Water SeparatorYes8x12Yes
26
1,501
  
1
YesYesYesNot specifiedWHKnoxville Utilities Board
1
Information not availableInside GarageInside Garage
27
1,502
  
1
NoYes30-50 ft from proposed washpadYesCovered wash pad and a sand/grit interceptor with particular specifications (attached to hard copy of summary)AEAlcoa Water and Sewer 865-981-4176:  Andy Sonner:Stated that TDOT is next to 303D stream Pistol Creek.  Possible diesel seep into creek.  Need to send plans and a grease trap permit.  Kenny Hendrix:865-981-4143.  Planning Commission: Chris Hamby:3804730
1
04/25/2001; sewer connection 3/3/02Metal22x32, Drive on/Drive off, openHydro Engineering HE/SI Oil Water Separator8x12Yes
28
1,503
  
0
CompleteNot specifiedYes350 ft from buildingNoCovered wash pad and a sand/grit interceptor with particular specifications (attached to hard copy of summary)AESevierville Engineering and Public Works (Water and Sewer) 423-453-5522:  Mike Williams
0
Concrete22x36, Drive on/Back offHydro Engineering HE/SI Oil Water Separator8x12Yes
29
2,201
  
0
CompleteNot on locationYesNoapproved wash pad, oil skimmer, sand trap, and coveringAEDunlap Wastewater Treatment Plant; Bill Finley or Clayton Smith 423/949-2115 (City Hall)
0
Concrete22x36, Drive on/Back offHydro Engineering HE/SI Oil Water Separator8x12
30
2,202
  
0
NoNoNoNo access to sewerNA- tank containment neededX
1
36971MetalNAHydro Engineering HE/SI Oil Water SeparatorYes8x12Yes
1 - 30Next